Press

Heat Tracing Cables - Self Regulating v Constant Wattage Heating Cables


Heat Tracing Cables Heat Tracing Cables

Heating Cables

What Is Heat Tracing?

Trace heating is the application of a controlled amount of electric surface heating to pipework, tanks, valves or process equipment to either maintain its temperature (by replacing heat lost through insulation, also referred to as frost protection) or to affect an increase in its temperature - this is done by using heating cables commonly referred to as heat trace or heat tracing cables.

The primary function of heat trace cable systems is the prevention of freezing within water pipes and subsequently bursting.

With temperatures dropping during the Winter months, freezing pipes are always a major concern for homeowners, businesses and industry alike. By maintaining the ambient temperature inside the pipe, frost cannot build up and pipes will not freeze.

This means pipes will not burst due to ice expansion - in this article we discuss the pros and cons of 2 types of heating cables; self-regulating and constant wattage.

 :idea: Did You Know.....  A gallon of water, when frozen, will expand to a volume 9% greater than the original gallon.

In addition to frost protection, heat tracing cables provide heat maintenance and heat recovery in the process and hazardous area industries.

Heating Cables Heat Tracing Cables: Preventing Frozen Pipes

How Do Heat Tracing Cables Work?

This can be achieved simply by connecting a voltage across a length of wire, which will then dissipate a fixed level of power, based on ohms law. In application, such a simplified solution presents certain complications in application.

For one thing, it results in the need to bring both ends of the wire together for connection to the electrical supply, which is not always practical when installing heating cables.

Additionally, it requires the need for a high variety of different resistances to be available, in order to facilitate the design of different outputs at different lengths of heating cable. There are many occasions where this approach is in fact still the best solution.

However, there is also an alternative in the form of parallel heat tracing cables.

Burst Water Mains Due To Frozen Pipe

Burst Water Mains Due To Frozen Pipe

Parallel Heat Tracing Cables

Constant Wattage & Self Regulating

Parallel heating cables are typically available in two distinct variants; constant wattage and self regulating (also known as self limiting).

Parallel Heat Tracing Cables

Parallel heat tracing cables use two ‘normal' copper conductor wires which run in parallel along the length of the wire and form the basis of live and neutral. The heat load is then created by two different methods. In the case of constant wattage cables, a fixed resistance filament is then spiralled along the length of the cable and soldered alternately to the live and neutral wire in fixed distances creating what are referred to as heating zones.

Essentially, every zone is a fixed resistance circuit supplied by a fixed voltage, providing a constant wattage along its length. Since each zone of heating is essentially in parallel with the zone before it, the supply voltage will remain constant along the length of the heating cable, aside from a small voltage drop brought about by the summation of the tiny resistances of the live and neutral wires as the cable gets longer and longer.

The first and most widely needed benefit of heat tracing systems is the prevention of freezing within pipes and with temperatures dropping daily, freezing pipes are now a major concern for homeowners, businesses and industry alike. By maintaining the ambient temperature inside the pipe, frost cannot build up and pipes will not freeze. This means pipes will not burst due to ice expansion.

Heat Trace Cables
Heat Tracing Pipes - How Frozen Water Will Burst Your Pipes If Not Frost Protected by Heating Cables

Self Regulating Heat Tracing CablesHeat Tracing Cables

Self regulating or self limiting heat tracing cables in effect also provide a controlled wattage per metre of cable but with a distinct difference, both in terms of construction and performance.

The live and neutral wires are co-extruded into a polymer based material containing particles of carbon, providing a resistance path and hence circuit along the length of the heating cable.

However, this resistance and therefore the output of the heating cable varies depending upon the temperature, due to microscopic expansion and contraction of the polymer.

This type of cable then has the feature of reducing its power output as temperature increases and conversely at lower temperatures, the power is increased.

Eltherm Heating Cables - Self Limiting Heat Tracing Cables Eltherm Heating Cables - Self Limiting Heat Tracing Cables

Self regulating heat tracing cables have an improved level of inherent efficiency as well as increased safety, if its application is correctly considered. Starting with the former, at higher temperatures the heating cable backs off its output, saving power even if not connected via a controller or thermostat.

This is not to say it will hold a fixed target temperature without external control, but the reduction of output as the work-piece temperature increases is a desirable feature from an energy conservation perspective.

This also gives rise to another highly desirable characteristic of self regulating cables, which is the ability to assign a T class (temperature rating) for ATEX purposes and safe installation in hazardous area locations. With the decrease in power output as the cable temperature increases, it is not possible for the cable to affect an increase to a temperature beyond a certain level, regardless of the level of thermal insulation used.

Eltherm Self Regulating Heat Tracing Cable For Hazardous Areas 

Constant Wattage Heat Tracing Cables

Constant wattage heat tracing cables do not vary its output depending on temperature and there are times where this is an advantage. Principally, if a higher maintenance temperature is required, constant wattage cable is sometimes preferred since a lower w/m variant may be used (as opposed to self regulating cable, where there would be the need to allow for the reduction in output due to elevated temperatures).

Since there is little inrush current with a constant wattage cable, it is also possible in general to use it in longer circuit lengths, particularly for higher output variants as opposed to similar self regulating versions.

One of the key benefits of parallel heating cables (self regulating or constant wattage) is the ability to cut the cable to length from a drum on site, without the need to consider the resistance of the wire itself.

Constant Wattage Heat Tracing Cables - Advantages

  • Single end power input
  • Can be cut off the roll
  • Constant power output per meter
  • Long life cycle
  • Laying without exact measuring possible
  • High chemical resistance
  • UV resistance
  • Suitable for hazardous area pipe heating
Heat Trace Heat Trace Cables: Thermal insulation is recommended on all heat trace applications to industrial or process pipework. Without suitable insulation heat losses can increase approx 4-5 times.

Heat Tracing Experience From The ExpertsHeat Tracing

Thorne & Derrick have almost 35 years trace heating experience.

Frost protection has always been core to our business growth with over 1 million meters of cable installed in the UK alone.

Schools, hospitals, sports stadia, prisons, hotels and other commercial buildings have T&D's heating cables preventing their pipes from freezing. Some of our more prestigious projects include Liverpool Echo Arena, Wembley Stadium and The Shard and we are very proud to have secured such contracts.

Roof & Gutter Heating

As well as frost protection of pipes, heat tracing cables can also be used to prevent frost, snow and ice build up in gutters and on ramps and access ways.

Roof and gutter heating cables can be installed in gutters and on rooftops to provide gentle warming which melts any snow/ice as it falls.

This maintains a flow path for the water and prevents gutters overflowing and water seeping back into the building. Melt water which cannot freely drain away will form pools which in turn can penetrate seams and joints in gutters and flat roofs causing serious damage to the internal building fabric and contents.

A leaking gutter or roof can cause extensive structural damage within buildings. Heat tracing cables create a flow path for the water allowing it to drain away correctly.

In some cases, the load bearing weight of any snow accumulation is the primary concern as the additional weight can negatively affect the structural integrity of the building.

Roof & Gutter Heating
Heat Tracing Cables Are Designed To Prevent Roof & Gutter Damage Caused By Winter Weather. Bronx CVS Roof Collapses Due To Snow Build-Up. Image : New York Post.[/caption]

Ramp Heating

Heat tracing cables can also be buried in concrete to heat up the surface temperature and prevent snow and ice accumulation. This is particularly beneficial to car park ramps which are exposed to the elements.

T&D were recently involved with the design and supply of a ramp heating system to Sainsbury's in Bicester. At the time, it was the largest ramp heating installation in the UK with over 3 kilometres of heating cables installed. Both self regulating and contact wattage heat tracing cables can be used for this application.

Typically, the construction of the ramp governs which type of cable would be selected and offer the most benefits. For example, self regulating heating cables are not suitable for direct burial into asphalt as they can not be exposed high elevated temperatures whereas a major advantage of constant wattage cables is the ability to be exposed such temperatures.

Conversely a constant wattage cable gives out a constant power output and offers no energy efficiency compared to a self regulating cable.

Ramp Heating
Ramp Heating Using Eltherm ELSR Heat Tracing Cables

Eltherm are a global leader in the manufacture of self regulating and constant wattage heating cables producing the full spectrum of variants with options for highly corrosive resistant fluoropolymer outer jackets. Research and development is a permanently on-going process, fed with input from their large projects and applications team, ensuring that products are designed and built to the highest standard and for the applications  of the modern world.

More Reading
Hazardous Area Electrical Equipment & Products Hazardous Area Electrical Equipment & Products

Trace Heating Systems & Heat Trace Cables

The heat trace cable ranges stocked and supplied by Thorne & Derrick International includes electric heating cables for process temperature maintenance, pipe and vessel freeze protection and roof and gutter de-icing applications where snow and ice removal is required - cables and systems are available for commercial, industrial safe area (non-hazardous area) and hazardous area heating applications with ATEX certification.

Electric heat tracing is a cable based system used to maintain, raise temperature and protect process pipework and vessels against freezing temperatures and associated frost damage - heat tracing cables mitigate and counteract cold weather effects as part of a Winterization strategy for industrial and process applications against low (sub-zero) ambient temperatures on both onshore and offshore locations.

Heat tracing systems utilising self-regulating, constant wattage and mineral insulated (MI) heating cables are available to provide the optimum electrical heating system for your application - we provide a trace heating system design service.

Heat Trace Cables: Ramp Heating | Roof & Gutter Heating | Water Pipework Frost Protection | Hopper Heating | Tank Heating | Hazardous Area Heating | Fire Escapes

Trace Heating Heat Trace Cables Trace Heating & Heat Tracing Cable Systems Specialists | Thorne & Derrick[/caption]



New service from OilVoice
Trip Shepherd is for companies who need to track their staff in areas of risk.
It's free to use, so we invite you to try it.

Visit source site

https://heatingandprocess.com/heat-tracing-cables-...

More items from nlundie


IECEx Fans | First Industrial Fan Manufacturer Obtains IECEx Certification

IECEx Certification for Industrial Fans | Hazardous Areas & Explosive Atmospheres Uploaded by Natalie Lundie |Supply Chain: Marketing Lead at Thorne & Derrick International Republished with kind permission of Woodcock & Wilson and IEC e-tech | News & Views from the IEC IECEX FANS W ...

Natalie Lundie


Posted 19 hours agoPress

ATEX & IECEx Panelboards | Distribution Boards for Heat Trace & Lighting Systems in Hazardous Area Locations

Hazardous Area & Explosion Proof Electrical Equipment Republished by Thorne & Derrick with kind permission of Emerson AppletonUploaded by Chris Dodds | Sales Marketing Manager Thorne & Derrick International HAZARDOUS AREA LIGHTING & POWER PANELBOARDS ATEX & IECEX  For Global Hazar ...

Natalie Lundie


Posted 7 days agoPress

Winterisation & Freeze Prevention of Water Pipes Onboard Tanker

Pictured:  Below is a 15kW  Hazloc AEU1  hazardous location heater with a factory built-in electronic thermostat to provide freeze prevention installed on the Torm Almena vessel. The  explosion proof heater  is used onboard oil and chemical tankers where it provides heat to the ballast water ...

Natalie Lundie


Posted 14 days agoPress

ATEX & IECEX Junction Boxes | Marechal B2X | NEW PRODUCT LAUNCH

ATEX & IECEx Junction Boxes MARECHAL B2X JUNCTION BOXES ATEX Junction Boxes For Hazardous Area Lighting & Power Systems Thorne & Derrick, the UK Distributor for  Marechal Electric , are pleased to announce the launch of a range of ATEX junction boxes to provide LV low voltage power distri ...

Natalie Lundie


Posted 18 days agoPress

How to Achieve Energy Efficiency With Carbon Reductions by ATEX LED Lighting Upgrades

ATEX LED Lighting uploaded by Chris Dodds | Thorne & Derrick Sales Marketing Manager LIGHTING HAZARDOUS AREAS There is an international trend in the global hazardous area industry sector to upgrade conventional  ATEX lighting  to use energy-efficient LED lighting technology. The sp ...

Natalie Lundie


Posted 1 month agoPress
All posts from nlundie